one platform for everything a building does
Heating, cooling, ventilation, lighting, shading, access, metering and alarms — one system, one BMS, one supplier responsible. Bisly hardware and software, configured in a digital twin and run from bisly.cloud.
What it controls
Every building function, per unit and for common areas
01
Heating and cooling
Room by room: radiators, floor heating, fan-coils, split and VRF units; pre-heat on occupancy; hydronic balancing support.
02
Ventilation and air quality
AHUs from 20+ manufacturers; CO₂ and humidity demand control per room; heat-recovery supervision.
03
Lighting
DALI-2 presence and daylight control; existing wall switches reused as inputs; Matter lighting where no cabling exists.
04
Blinds and shading
By sun position, glare and occupancy; scenes per room and per facade.
05
Access and intercom
Readers, locks, video intercom and lifts in the same BMS, with per-tenant credentials and time rules.
06
Metering and billing
Electricity, heat, water and gas per meter and per tenant; billing-ready exports; spike alarms.
07
Price-based control
Day-ahead prices shift setpoints and loads; links to EV charging and storage from AMP X VOLT.
08
Security and alarms
Leak, smoke, open window and intrusion inputs; prioritised alarms by SMS and e-mail, with the room named.
Lighting
Dimmable, daylight-led and circadian
Presence and lux sensors measure the light in every zone; the controller compares it with the required level and sets the dimmers, so daylight comes first and the luminaires add only what is missing. Scenes set a room for work, meetings, presentations, dinner or cleaning. Tunable white follows the natural day — brighter and cooler in the morning, warmer and lower in the evening — to support the circadian rhythm, mood and sleep. Bisly developed its human-centric lighting control with TalTech.
- DALI-2 on the same system as heating and ventilation: DALI Bridge 2 with 64 drivers per line, colour and tunable white (DT6/DT8), Presence Sensor with lux measurement
- Matter lights and wall switches where there are no control cables (Bisly Wireless)
- Scenes from the wall panel, the app, a push button or the schedule
- Savings by space: open office 7–36 %, office rooms 10–70 %, meeting rooms 22–64 %, classrooms 14–76 %, toilets 33–90 % (Bisly figures)
- Average savings in an LBNL meta-analysis: 24 % from occupancy control, 28 % from daylighting, 38 % from combined strategies (Williams et al., 2012)
- Supports WELL v2 feature L03 Circadian Lighting Design and BREEAM Hea 01 Visual comfort
Digital twin
Configured, not programmed
Labour is 50–75% of a conventional controls project (NREL/JISEA, 2022). Bisly removes that part: every function is a configuration choice in the digital twin, so no controller code is written for any site.
- 01Sell: the Sales Configurator builds floors, rooms and functions.
- 02Win: quote and bill of materials per room and per panel.
- 03Generate: wiring, panel configuration and logic, pre-configured and factory-tested.
- 04Install: the Installer App — room first, device second, no laptop at the panel; automated documentation.
- 05Operate: the twin stays live in the BMS and becomes the template for the next building.
BMS and Adam
What the facility manager finds where
bisly.cloud runs in any browser, with a mobile app for alerts and overrides. One login covers a whole portfolio.
- 01
Rooms and spaces
Floor plans with live temperature, CO₂ and humidity per room, coloured by state, with alarm badges. The room behind a complaint is found in seconds.
- 02
Equipment
Live schematics of substations, heat pumps and AHUs; setpoints, modes and heating curves edited on the schematic.
- 03
Meters
Electricity, heat, water and gas per meter, virtual meters, day/night split, tenant allocation; PDF, CSV and Excel.
- 04
Alarms
Priorities, delays, comments, SMS and e-mail; silent sensors and stuck actuators detected automatically.
- 05
Schedules and automations
Per AHU, lighting group, room or tenancy, with a holiday calendar and every run on a timeline.
- 06
Trends
1-minute data for 30 days, 15-minute for a year, hourly for five years; Excel export.
- 07
Adam, the AI assistant
Explains sensor drift, stuck actuators and short cycling in plain language; ranks a portfolio by energy, indoor air and alarms.
Wired hardware
The 2026/27 device family
Industrial hardware on 24 V DC DIN rail, RS-485 trunks and BACnet/IP — one panel per floor or zone.
| Code | Device | Role |
|---|---|---|
| CX00 | Bisly Server | On-site brain for HVAC, lighting, access and energy; logic and schedules keep running through internet outages; BACnet/IP server, BACnet/IP and Modbus TCP client |
| CX01 | Mini Server | Runs a substation, AHU plant room or small site on its own |
| CU08 | Controller 8 | One per floor or zone: 8 × 16 A relays, 8 digital and 4 analog inputs, 1-Wire, 3 RS-485 trunks; updated over the air |
| IA08 · IQ08 · IR08 | I/O modules | 8 analog inputs (0–10 V, 4–20 mA) · 8 analog outputs (0–10 V, 12-bit) · 8 changeover relays |
| RC04 | Room Controller 4 | 3.5" glass touch; temperature and humidity, optional CO₂/VOC and presence; drives fan-coil, radiator, floor heating |
| RP10 | Bisly Hub | 10.1" PoE wall panel: light, climate, door, intercom, booking |
| LD02 · SP01-D2 | DALI Bridge 2 · Presence Sensor | One DALI-2 line, 64 control gears, DT6/DT8 colour; presence and lux with daylight harvesting |
| GA01 | AC Gateway 1 | Split, multi-split and VRF indoor units: setpoint, mode, fan speed, fault codes |
| GM250 | M-Bus Gateway 250 | 250 wired M-Bus loads (about 180 meters) plus wireless M-Bus (OMS); automatic meter discovery |
Source: Bisly Commercial Buildings Catalogue 2026/27.
Integrations
Any brand, no lock-in
The developer chooses the manufacturer for every building system; the platform connects it. A brand that is missing is integrated by Bisly at no charge and made available to every project.
Every system in the building, on one platform
01
Heating and cooling
- Modbus RTU/TCP
- BACnet/IP
- M-Bus heat meters
- VRF via AC Gateway 1
02
Ventilation
- AHUs from 20+ vendors
- Modbus
- BACnet/IP
- 0–10 V
- CO₂ demand control
03
Lighting and shading
- DALI-2
- Matter over Thread
- Relays
- Blinds by sun and occupancy
04
Metering
- Wired M-Bus
- Wireless M-Bus (OMS)
- Modbus RTU
- Pulse inputs
05
Access and security
- OSDP readers
- SIP intercoms (2N)
- ONVIF cameras
- Lift API
06
Third-party systems
- KNX via KNX/IP gateway
- BACnet/IP server and client
- REST API
- Matter devices
Architecture and security
Local control first, cloud second
Runs on site
The Bisly Server keeps logic, schedules and alarms running during an internet outage. Plant rooms can run autonomously on the Mini Server.
Isolated network
A dedicated automation LAN with pre-configured router and PoE switches, one outbound HTTPS uplink, per-port status in the BMS.
Open interfaces
BACnet/IP server for third-party head-ends, documented REST API with tokens per integration, published register maps.
What it saves
Savings compound only when the full stack is installed
A thermostat alone saves little. Room control, hydronic balancing and plant optimisation together are where the 20%+ comes from.
Smart radiator thermostat on its own
EDF / Vestemi, Radbot Smart TRV, Ofgem 2022
~3%
Room-level control across the building
Cholewa, Siuta-Olcha & Balaras, Energy and Buildings 151, 2017
~10%
Room control plus hydronic balancing
Same study, same buildings
~21%
Plus forecast-based plant control
A further 11–13%: Cholewa et al., Energy and Buildings 292, 2023
+11–13%
Full Bisly stack, 30+ schools and public buildings
Bisly portfolio, 20–35%
20–35%
% energy saved