one platform for everything a building does

Heating, cooling, ventilation, lighting, shading, access, metering and alarms — one system, one BMS, one supplier responsible. Bisly hardware and software, configured in a digital twin and run from bisly.cloud.

What it controls

Every building function, per unit and for common areas

01

Heating and cooling

Room by room: radiators, floor heating, fan-coils, split and VRF units; pre-heat on occupancy; hydronic balancing support.

02

Ventilation and air quality

AHUs from 20+ manufacturers; CO₂ and humidity demand control per room; heat-recovery supervision.

03

Lighting

DALI-2 presence and daylight control; existing wall switches reused as inputs; Matter lighting where no cabling exists.

04

Blinds and shading

By sun position, glare and occupancy; scenes per room and per facade.

05

Access and intercom

Readers, locks, video intercom and lifts in the same BMS, with per-tenant credentials and time rules.

06

Metering and billing

Electricity, heat, water and gas per meter and per tenant; billing-ready exports; spike alarms.

07

Price-based control

Day-ahead prices shift setpoints and loads; links to EV charging and storage from AMP X VOLT.

08

Security and alarms

Leak, smoke, open window and intrusion inputs; prioritised alarms by SMS and e-mail, with the room named.

Lighting

Dimmable, daylight-led and circadian

00:0006:0012:0018:0000:00Light level and colour temperatureRoom light now12:00 · 5,500 K · 100 %
Illustration of human-centric lighting: tunable white follows the natural day, warm and low in the evening, bright and cool around midday. Bisly developed its human-centric lighting control with TalTech.

Presence and lux sensors measure the light in every zone; the controller compares it with the required level and sets the dimmers, so daylight comes first and the luminaires add only what is missing. Scenes set a room for work, meetings, presentations, dinner or cleaning. Tunable white follows the natural day — brighter and cooler in the morning, warmer and lower in the evening — to support the circadian rhythm, mood and sleep. Bisly developed its human-centric lighting control with TalTech.

  • DALI-2 on the same system as heating and ventilation: DALI Bridge 2 with 64 drivers per line, colour and tunable white (DT6/DT8), Presence Sensor with lux measurement
  • Matter lights and wall switches where there are no control cables (Bisly Wireless)
  • Scenes from the wall panel, the app, a push button or the schedule
  • Savings by space: open office 7–36 %, office rooms 10–70 %, meeting rooms 22–64 %, classrooms 14–76 %, toilets 33–90 % (Bisly figures)
  • Average savings in an LBNL meta-analysis: 24 % from occupancy control, 28 % from daylighting, 38 % from combined strategies (Williams et al., 2012)
  • Supports WELL v2 feature L03 Circadian Lighting Design and BREEAM Hea 01 Visual comfort

Digital twin

Configured, not programmed

Labour is 50–75% of a conventional controls project (NREL/JISEA, 2022). Bisly removes that part: every function is a configuration choice in the digital twin, so no controller code is written for any site.

  1. 01Sell: the Sales Configurator builds floors, rooms and functions.
  2. 02Win: quote and bill of materials per room and per panel.
  3. 03Generate: wiring, panel configuration and logic, pre-configured and factory-tested.
  4. 04Install: the Installer App — room first, device second, no laptop at the panel; automated documentation.
  5. 05Operate: the twin stays live in the BMS and becomes the template for the next building.
Meeting 2.1224 m²Office 2.1424 m²Office 2.1624 m²Open office 2.1052 m²Meeting 2.2032 m²RiserCorridor24.0 mCU0838 devices · 1 panel · one budget21.5 °C640 ppm22.0 °C710 ppm21.8 °CEmpty, set back22.1 °C820 ppm, airflow up19.4 °CWindow open, heating paused

BMS and Adam

What the facility manager finds where

bisly.cloud runs in any browser, with a mobile app for alerts and overrides. One login covers a whole portfolio.

  1. 01

    Rooms and spaces

    Floor plans with live temperature, CO₂ and humidity per room, coloured by state, with alarm badges. The room behind a complaint is found in seconds.

  2. 02

    Equipment

    Live schematics of substations, heat pumps and AHUs; setpoints, modes and heating curves edited on the schematic.

  3. 03

    Meters

    Electricity, heat, water and gas per meter, virtual meters, day/night split, tenant allocation; PDF, CSV and Excel.

  4. 04

    Alarms

    Priorities, delays, comments, SMS and e-mail; silent sensors and stuck actuators detected automatically.

  5. 05

    Schedules and automations

    Per AHU, lighting group, room or tenancy, with a holiday calendar and every run on a timeline.

  6. 06

    Trends

    1-minute data for 30 days, 15-minute for a year, hourly for five years; Excel export.

  7. 07

    Adam, the AI assistant

    Explains sensor drift, stuck actuators and short cycling in plain language; ranks a portfolio by energy, indoor air and alarms.

Wired hardware

The 2026/27 device family

Industrial hardware on 24 V DC DIN rail, RS-485 trunks and BACnet/IP — one panel per floor or zone.

CodeDeviceRole
CX00Bisly ServerOn-site brain for HVAC, lighting, access and energy; logic and schedules keep running through internet outages; BACnet/IP server, BACnet/IP and Modbus TCP client
CX01Mini ServerRuns a substation, AHU plant room or small site on its own
CU08Controller 8One per floor or zone: 8 × 16 A relays, 8 digital and 4 analog inputs, 1-Wire, 3 RS-485 trunks; updated over the air
IA08 · IQ08 · IR08I/O modules8 analog inputs (0–10 V, 4–20 mA) · 8 analog outputs (0–10 V, 12-bit) · 8 changeover relays
RC04Room Controller 43.5" glass touch; temperature and humidity, optional CO₂/VOC and presence; drives fan-coil, radiator, floor heating
RP10Bisly Hub10.1" PoE wall panel: light, climate, door, intercom, booking
LD02 · SP01-D2DALI Bridge 2 · Presence SensorOne DALI-2 line, 64 control gears, DT6/DT8 colour; presence and lux with daylight harvesting
GA01AC Gateway 1Split, multi-split and VRF indoor units: setpoint, mode, fan speed, fault codes
GM250M-Bus Gateway 250250 wired M-Bus loads (about 180 meters) plus wireless M-Bus (OMS); automatic meter discovery

Source: Bisly Commercial Buildings Catalogue 2026/27.

Integrations

Any brand, no lock-in

The developer chooses the manufacturer for every building system; the platform connects it. A brand that is missing is integrated by Bisly at no charge and made available to every project.

Every system in the building, on one platform

01

Heating and cooling

  • Modbus RTU/TCP
  • BACnet/IP
  • M-Bus heat meters
  • VRF via AC Gateway 1

02

Ventilation

  • AHUs from 20+ vendors
  • Modbus
  • BACnet/IP
  • 0–10 V
  • CO₂ demand control

03

Lighting and shading

  • DALI-2
  • Matter over Thread
  • Relays
  • Blinds by sun and occupancy

04

Metering

  • Wired M-Bus
  • Wireless M-Bus (OMS)
  • Modbus RTU
  • Pulse inputs

05

Access and security

  • OSDP readers
  • SIP intercoms (2N)
  • ONVIF cameras
  • Lift API

06

Third-party systems

  • KNX via KNX/IP gateway
  • BACnet/IP server and client
  • REST API
  • Matter devices

Architecture and security

Local control first, cloud second

Runs on site

The Bisly Server keeps logic, schedules and alarms running during an internet outage. Plant rooms can run autonomously on the Mini Server.

Isolated network

A dedicated automation LAN with pre-configured router and PoE switches, one outbound HTTPS uplink, per-port status in the BMS.

Open interfaces

BACnet/IP server for third-party head-ends, documented REST API with tokens per integration, published register maps.

What it saves

Savings compound only when the full stack is installed

A thermostat alone saves little. Room control, hydronic balancing and plant optimisation together are where the 20%+ comes from.

  1. Smart radiator thermostat on its own

    EDF / Vestemi, Radbot Smart TRV, Ofgem 2022

    ~3%

  2. Room-level control across the building

    Cholewa, Siuta-Olcha & Balaras, Energy and Buildings 151, 2017

    ~10%

  3. Room control plus hydronic balancing

    Same study, same buildings

    ~21%

  4. Plus forecast-based plant control

    A further 11–13%: Cholewa et al., Energy and Buildings 292, 2023

    +11–13%

  5. Full Bisly stack, 30+ schools and public buildings

    Bisly portfolio, 20–35%

    20–35%

% energy saved

Questions

Platform questions

Does Bisly support daylight harvesting and human-centric (circadian) lighting?

Yes. DALI-2 Presence Sensors measure the lux level per zone and the luminaires dim to hold the required level with daylight first. Tunable white (DALI-2 DT8) follows the natural day for the circadian rhythm; Bisly developed this human-centric lighting control with TalTech. Scenes run from the wall panel, the app, push buttons or schedules, on the same system as heating and ventilation.

What is the difference between BACS and BMS?

BACS (building automation and control system) is the whole system of controllers, sensors, actuators and logic that runs the building. The BMS (building management system) is the software layer where people monitor and adjust it. Bisly supplies both, from one vendor.

What happens if the internet connection fails?

The building keeps running. Logic, schedules and alarms run on the on-site Bisly Server; the cloud is used for remote access, data history and portfolio views.

Who owns the data?

The building owner. Data is available through the BMS exports, the BACnet/IP server and a documented REST API, so it can feed property-management, ESG or energy platforms.

Can residents use their own smart-home devices?

Matter-certified devices can join the system, and residents control climate, light, blinds, access and scenes through the Bisly app or wall panels.

See the platform running in our showroom in Hamm