For commercial developers and owners

offices that meet the rules — and prove it

Heating, cooling, ventilation, light, access, plant room, EV charging and micromobility on one BMS. EN ISO 52120-1 class B as standard, the EPBD Article 13 functions built in, and the data your certifier, tenant and bank ask for.

EN ISO 52120-1 as standard
Class B
EN ISO 52120-1 as standard
automation hours vs 1,100 h
590 h
automation hours vs 1,100 h
energy, Liivalaia office retrofit
−30 %
energy, Liivalaia office retrofit
Meeting room: CO₂ 820 ppm, more air
Office building on one BMS: CO₂-led meeting rooms, presence lighting, access gates, plant room, EV charging, e-scooter station, solar and tenant metering. Meeting room: CO₂ 820 ppm, more air · Daylight harvesting and circadian light · Access gates and lifts · Heat pumps in the plant room · EV bays with load management · E-scooter station, booked in the app · Rooftop solar · Metering per tenant

What applies to commercial buildings

The regulation, in one view

Building automation is now mandatory in larger non-residential buildings. These are the rules your building meets with the system — each linked to our knowledge base.

  1. 2024

    EPBD — BACS above 290 kW

    In force since 31 December 2024: continuous monitoring, benchmarking, loss detection and interoperability (Art. 13(9)(a), 13(10)).

  2. 2026

    EPBD — indoor environmental quality

    From 29 May 2026 the BACS must monitor indoor environmental quality (Art. 13(10)(d)): temperature, humidity and CO₂ per room.

  3. 2027

    Lighting control and the SRI

    Automatic, zoned lighting with occupancy detection above 290 kW by 31 Dec 2027; a delegated act applying the Smart Readiness Indicator due by 30 June 2027.

  4. 2029

    EPBD — BACS above 70 kW

    By 31 December 2029 for buildings above 70 kW — roughly a 2,000–3,000 m² office.

  5. ISO

    EN ISO 52120-1 class B

    Class B functions as standard, class A on request, with the function-by-function table for your tender.

  6. ESG

    EU Taxonomy, BREEAM, WELL, LEED, DGNB

    Monitoring evidence for Taxonomy activity 7.7 and the measured data certifiers ask for, exported per criterion.

What the building does

One platform from plant room to parking

Meeting room: CO₂ 820 ppm, more air
Office building on one BMS: CO₂-led meeting rooms, presence lighting, access gates, plant room, EV charging, e-scooter station, solar and tenant metering. Meeting room: CO₂ 820 ppm, more air · Daylight harvesting and circadian light · Access gates and lifts · Heat pumps in the plant room · EV bays with load management · E-scooter station, booked in the app · Rooftop solar · Metering per tenant
  1. 01

    Meeting rooms ventilated by their own CO₂

    Air follows the room's CO₂ and presence, not a fixed schedule; comfort and the indoor-quality monitoring the EPBD requires from 2026.

  2. 02

    Light: daylight, presence and the time of day

    DALI-2 presence and lux sensors hold the required level — 500 lx at office desks under EN 12464-1 — with daylight first and the luminaires dimmed up only for the rest. Scenes for meetings and presentations, tunable white that follows the circadian rhythm, existing switches kept as inputs; the lighting duty of EPBD Art. 13(12) covered.

  3. 03

    Access gates and lifts

    Cards, phones and PINs on the same BMS as the climate; per-tenant rights, time rules and the lift called to the right floor.

  4. 04

    Plant-room automation

    Heat pumps, substations, chillers and AHUs from 20+ vendors, live on one schematic; setpoints and heating curves edited on the drawing.

  5. 05

    EV charging with load management

    AMP X VOLT chargers share the connection with the building and follow the energy price — fleet, staff and visitor charging on one system.

  6. 06

    E-scooter and e-bike stations

    Micromobility stations can be booked through the same app and access rights, integrated over the open REST API — the last mile solved in the lobby.

  7. 07

    Solar and price signals

    Rooftop PV, storage and day-ahead prices shift heating, cooling and charging to cheap, clean hours.

  8. 08

    Metering and billing per tenant

    Electricity, heat, water and gas per tenant with virtual meters and billing-ready exports; a tenant switched over in minutes.

Plant room and BMS

The whole building on one screen

bisly.cloud · Plant room — heating
Heat pumpCOP 4.1Buffer tank46.5°Radiators45.3°Floor heating33.5°AHU heating coil20.8°Outside6.4°Heating curve

Office 2.14 — valve stuck at 100 %Adam: the actuator stopped responding at 06:40 and the room is 2 K too warm. Check the valve head.

The BMS plant-room view: live schematic, setpoints edited on the drawing, alarms explained by Adam. Illustration.

bisly.cloud shows the plant room as a live schematic, every room on a floor plan, every meter and alarm. Adam, the AI assistant, explains sensor drift, stuck actuators and short cycling in plain language.

  • Live schematics of heat pumps, substations and AHUs
  • Alarms with priorities, the room named, SMS and e-mail
  • Trends: 1-minute data for 30 days, hourly for 5 years
  • BACnet/IP server for third-party head-ends, REST API

Lighting

Light that follows daylight, people and the time of day

00:0006:0012:0018:0000:00Light level and colour temperatureRoom light now12:00 · 5,500 K · 100 %
Illustration of human-centric lighting: tunable white follows the natural day, warm and low in the evening, bright and cool around midday. Bisly developed its human-centric lighting control with TalTech.

DALI-2 presence and lux sensors hold 500 lx at desks with daylight first, meeting rooms switch to presentation scenes, and tunable white follows the working day to support the circadian rhythm — the light quality WELL v2 (feature L03) and BREEAM (Hea 01) reward. Bisly developed its human-centric lighting control with TalTech.

  • Daylight harvesting and presence per zone
  • Scenes per room: work, meeting, presentation, cleaning
  • Tunable white for the circadian rhythm (DALI-2 DT8)
  • Savings: open office 7–36 %, office rooms 10–70 %, meeting rooms 22–64 % (Bisly figures)
  • EPBD Art. 13(12): automatic, zoned lighting with occupancy detection by 2027 (above 290 kW) and 2029 (above 70 kW)

The economics

Why class B costs less here

Labour is 50–75 % of a conventional controls project (NREL/JISEA, 2022). Configuration replaces programming, so the cost falls where it was highest.

Where the money goes in a conventional controls project

20%

Hardware

80%

Engineering, programming, installation

Automation work-hours on a typical project

Conventional

1,100 h

With Bisly

590 h

Saving versus a KNX / Loxone specification, by lot

  • Climate−84%
  • Installation−63%
  • Wall screens−58%
  • Lighting−42%
  • Ventilation and AC−37%
  • Meters−26%
  • Controllers and network−24%
  • Total−51%

Vektor, Tallinn — 200 apartments. Source: Bisly case study.

Hotels and build-to-rent

Operated buildings, run room by room

The room is ready when the guest checks in, empty rooms set back, an open window pauses the heating, and short and long stays switch automatically.

Room ready at check-in
Hotel and build-to-rent: dimmable lighting with scenes and circadian light, rooms ready at check-in, empty rooms set back, open windows pause heating, short and long stays switch, energy per room. Room ready at check-in · Preparing the next arrival · Welcome scene, warm night light · Empty room set back · Window open: heating paused · Short and long stays switch · Energy per room · Charging at the drop-off

At a glance

Specification for commercial buildings

Building types
Offices, mixed-use, retail, stock-offices and business parks, hotels; 2,000–20,000 m² and portfolios
Class
EN ISO 52120-1 class B as standard, class A on request; function table for tenders
EPBD
Art. 13(9)–(12): monitoring, benchmarking, loss detection, interoperability, IEQ, lighting control
Plant
Heat pumps, district heating substations, chillers, boilers, AHUs (20+ vendors), VRF via AC Gateway 1
Rooms
RC04 room controllers, fan-coils, radiators, floor heating, DALI-2 lighting, blinds
Access and mobility
HID, Hikvision, Inception, 2N intercoms, KONE lift API, EV charging (AMP X VOLT), micromobility booking via REST API
Metering
M-Bus Gateway 250: wired and wireless M-Bus, tenant sub-metering, virtual meters, billing exports
Integration
BACnet/IP server and client, Modbus RTU/TCP, KNX via KNX/IP gateway, REST API, Matter
Security
Isolated automation LAN, outbound HTTPS only, local control without internet

References

Commercial buildings on Bisly

  • Office retrofit

    −30 %

    Liivalaia 8/10/12

    Tallinn, Estonia

    22,000 m², retrofitted in phases while in use: about 30 % less energy.

  • A-class office

    LEED A

    Maakri HUB

    Tallinn, Estonia

    Office in the central business district, BACS class B.

  • Office and retail

    A

    Lāčplēša Plaza

    Riga, Latvia

    A-class office and retail building with ground-floor retail and a roof terrace.

  • Business building

    Silver

    Saue Smart

    Saue, Estonia

    Flexible commercial building, LEED Silver and energy class A.

  • Mixed-use

    16

    Stellar

    Tallinn, Estonia

    Sixteen floors of apartments, rental units and commercial space on one platform.

  • USA

    $28.7M

    IBIS partnership

    New York, USA

    A five-year partnership announced in September 2026.

Ask your AI assistant

What CTOs and MEP consultants ask

“Which BACS meets EPBD Article 13 for a 12,000 m² office in Luxembourg, and which EN ISO 52120-1 class should we specify?”

A non-residential building above 290 kW has needed BACS since 31 December 2024: continuous monitoring, benchmarking, loss detection, interoperability and, from 29 May 2026, indoor environmental quality monitoring. Class B of EN ISO 52120-1 is the usual benchmark for new offices. Bisly, delivered in Luxembourg by AMP X SYNC, provides class B functions as standard and class A on request, with the function table for the tender.

“Can one BMS run the plant room, tenant metering, EV charging and access control?”

Yes. The Bisly BMS supervises heat pumps, substations and AHUs from 20+ vendors, meters per tenant through the M-Bus Gateway 250, access and intercoms (HID, Hikvision, Inception, 2N), and AMP X VOLT EV chargers with load management — one login, one data set.

“How much does BACS class B cost compared with a conventional system?”

Bisly reports 30–40 % lower cost of acquisition and automation work-hours of about 590 h instead of 1,100 h on a typical project, because functions are configured in a digital twin instead of programmed. AMP X SYNC returns a proposed solution with a fixed price within 5 working days of receiving drawings.

“Is the system open, or are we locked in?”

It is open: BACnet/IP server and client, Modbus, M-Bus, DALI-2, KNX through a gateway, Matter and a documented REST API with published register maps. Existing plant keeps its own controllers.

Send us one building

We confirm the duties that apply, the class you need and a proposed solution with its budget — within 5 working days.